Series 5

Side flexing and spiral belts
Pitch 25 mm (0.98 in)


Series 5 – Excerpt from Prolink Engineering Manual

Design characteristics

  • Suitable for both straight and radius conveying
  • up to 45 % open area for excellent air circulation
    and drainage
  • Stainless steel hinge pins for high load capacity,
    lateral stiffness, fewer belt supports and minimum belt lifting in curves
  • No potential belt edge catch points due to safe fixing of hinge pins

Series 5 - Design characteristics

Basic data

Pitch 25 mm (0.98)
Belt width min.100 mm (3.9 in), 175 mm (6.9 in) for S5 ST
Width increments25 mm (0.98)
Hinge pinsStainless steel

Prolink Basic Data Series 5

S5-45 GRT | 45 % Opening | Grid top

  • Open area (45 %) for excellent air circulation and drainage
  • Lattice shaped surface

S5-45 GRT

S5-45 NTP | 45 % Opening | Nub top (round studs)

  • Open area (45 %) for excellent air circulation and drainage
  • Lattice shaped surface with 3.0 mm (0.12 in) high round studs and 8 % contact area
  • Side modules without NTP-surface

S5-45 NTP

S5-39 FRT1

  • Excellent air circulation and drainage
  • Integrated friction pads (raised) increase surface friction and provide gentle grip
  • Side modules without FRT-surface

S5-39 FRT1

S5-33 FRT2 | 33 % Opening | Friction top (Design 2)

  • Open area (33 % for full FRT2 surface area) for excellent air circulation and drainage
  • Integrated friction pads (flat) provide gentle grip

S5-33 FRT2

S5-45 GRT G | 45 % Opening | Grid top · guided

  • Excellent air circulation and drainage
  • Lattice shaped surface and Hold Down tabs
  • Allows utilisation of the entire belt width

S5-45 GRT G

S5-45 NTP G | 45 % Opening | Nub top (round studs) · guided

  • Excellent air circulation and drainage
  • With round studs for increased grip (8 % contact area)
  • Allows utilisation of the entire belt width
  • Side modules only available without NTP-pattern

S5-45 NTP G

S5-39 FRT1 G | 39 % Opening | Friction top (Design 1)

  • Excellent air circulation and drainage
  • Integrated friction pads (raised) increase surface friction and provide gentle grip
  • Allows utilisation of the entire belt width
  • Side modules without FRT-surface

S5-39 FRT1 G

S5-33 FRT2 G | 33 % Opening | Friction top (Design 2)

  • Open area (33 % for full FRT2 surface area) for excellent air circulation and drainage
  • Integrated friction pads (flat) provide gentle grip
  • Allows utilisation of the entire belt width
  • Side modules without FRT-surface

S5-33 FRT2 G

S5-45 GRT RG | 45 % Opening | Grid top · reversed guided

  • Excellent air circulation and drainage
  • Lattice shaped surface and reversed Hold Down tabs
  • Allows utilisation of the entire belt width

S5-45 GRT RG

S5-45 NTP RG | 45 % Opening | Nub top (round studs) · reversed guided

  • Excellent air circulation and drainage
  • With round studs for increased grip (8 % contact area)
  • Allows utilisation of the entire belt width
  • Side modules only available without NTP-pattern

S5 45 NTP RG

S5-39 FRT1 RG | 39 % Opening | Friction top (Design 1)

  • Excellent air circulation and drainage
  • Integrated friction pads (raised) increase surface friction and provide gentle grip
  • Allows utilisation of the entire belt width
  • Side modules without FRT-surface

S5-39 FRT1 RG

S5-33 FRT2 RG | 33 % Opening | Friction top (Design 2)

  • Open area (33 % for full FRT2 surface area) for excellent air circulation and drainage
  • Integrated friction pads (flat) provide gentle grip
  • Allows utilisation of the entire belt width
  • Side modules without FRT-surface

S5-33 FRT2 RG

S5-45 GRT ST | 45 % Opening | Grid top · strong

  • Excellent air circulation and drainage
  • Lattice shaped surface
  • Version with reinforced brick-laid side modules (75 mm/2.9 in and 100 mm/3.9 in) increases belt pull capacity

S5-45 GRT ST

S5-45 NTP ST | 45 % Opening | Nub top (round studs) · strong

  • Excellent air circulation and drainage
  • With round studs for increased grip (8 % contact area)
  • Version with reinforced brick-laid side modules increases belt pull capacity
  • Side modules only available without NTP-pattern

S5-45 NTP ST

S5-39 FRT1 ST | 39 % Opening | Friction top (Design 1)

  • Excellent air circulation and drainage
  • Integrated friction pads (raised) increase surface friction and provide gentle grip
  • Reinforced side modules increase belt pull capacity
  • Side modules without FRT-surface

S5-39 FRT1 ST

S5-33 FRT2 ST | 33 % Opening | Friction top (Design 2) · strong

  • Open area (33 % for full FRT2 surface area) for excellent air circulation and drainage
  • Lattice shaped surface
  • Version with reinforced brick-laid side modules increases belt pull capacity

S5-33 FRT2 ST

Sprockets

in different sizes with round or square sprocket bore

Series 5 - Sprockets

Profiles

in different heights and designs for inclines

Series 5 - Profiles

Side guards

in different heights for retention of bulk products

Series 5 - Side guards

Ball-bearing modules

to minimize friction forces at the belt edge

Series 5 - Ball-bearing modules
Combo Belts Teaser EN

Further Information

  • Ref.no.888-2_1.2_S5.pdf

    Series 5
    Excerpt from Prolink Engineering Manual

google-site-verification: google6bc5bacb351e9327.html