Air-cooled Splicing tools

Light-weight combo press

Siegling Blizzard – the turbo-cooled light-weight combo press

The Siegling Blizzard press is supplied with a flight case on castors. Because it’s so compact and lightweight, it’s quick and easy to set up. It’s ready to use as soon as you’ve plugged it into the mains because there’s no need to connect it to external subsystems.

  • The control unit,
  • compressor and
  • air cooling system are integrated in the press.

This saves time and costs, prevents errors during operation and ensures hygiene on site.


Get detailed information on how to use our Air-cooled Siegling Blizzard HP here – or download the App on your Mobile device using the QR-Code in the banner.

HP-QR-Code
Blizzard
Blizzard

Technical Info

Blizzard HP 160/400 AIRBlizzard HP 160/600 AIRBlizzard HP 160/800 AIRBlizzard HP 160/1000 AIRBlizzard HP 160/1200 AIRBlizzard HP 160/1500 AIR
Effective belt width [mm (in)]400 (15.7)600 (23.6)800 (31.5)1000 (39.4)1200 (47.2)1500 (59)
Max. effective splice length [mm (in)]160 (6.3)160 (6.3)160 (6.3)160 (6.3)160 (6.3)160 (6.3)
Weight Bottom part [kg (lb)]12 (26.5)15.8 (34.8)19.1 (42.1)22.5 (49.6)26.2 (57.8)31 (68.3)
Weight Top part [kg (lb)]14.6 (32.2)18.6 (41)22.7 (50)26.9 (59.3)30.9 (68.1)36.8 (81.1)
Total Weight [kg (lb)]26.6 (58.6)34.4 (75.8)41.8 (92.1)49.4 (108.9)57.1 (125.9)67.8 (149.5)
Length [mm (in)]590 (23.2)790 (31.1)990 (39)1190 (46.8)1390 (54.7)1690 (66.5)
Width [mm (in)]230 (9.1)230 (9.1)230 (9.1)230 (9.1)230 (9.1)230 (9.1)
Height Top part [mm (in)]118 (4.6)118 (4.6)118 (4.6)118 (4.6)118 (4.6)118 (4.6)
Height Bottom part [mm (in)]84 (3.3)84 (3.3)84 (3.3)84 (3.3)84 (3.3)84 (3.3)
Max. pressure [bar (psi)]2.5 (36.3)2.5 (36.3)2.5 (36.3)2.5 (36.3)2.5 (36.3)2 (29)
Max. temperature [°C (°F)]200 (392)200 (392)200 (392)200 (392)200 (392)200 (392)
Transport dimensions (L x W x H) [mm]875 x 370 x 350875 x 370 x 3501275 x 370 x 3501275 x 370 x 3501775 x 370 x 3501775 x 370 x 350
Transport dimensions (L x W x H) [in]34.5 x 14.6 x 13.834.5 x 14.6 x 13.850.2 x 14.6 x 13.850.2 x 14.6 x 13.869.9 x 14.6 x 13.869.9 x 14.6 x 13.8
Transport weight [kg (lb)]42.1 (92.8)49.9 (110)61.9 (136.5)69.5 (153.2)83.8 (184.8)94.5 (208.3)




Power requirements
1 phase [Volt / Amp/ Watt]230V / 9A / 2200W Art.No.873399 110V / 14A / 1520W Art.No.873400230V / 14A / 3200W Art.No.873401 110V / 14A / 1520W Art.No.873402230V / 16A / 3680W Art.No.873403 110V / 14.5A / 1600W Art.No.873404230V / 16A / 3680W Art.No.873405 110V / 14A / 1484W Art. No.873406230V / 16A / 3680W Art.No.873409230 V / 19.5 A / 4500 W Art. No. 873412 230V / 16.0A / 3680W Art.No.873413 230V / 13.0A / 3000W Art.No.873414
3 phase [Volt / Amp / Watt]400V / 11A-5.5 A-5.5A/ 7600W Art.No.873407400V / 12A-6.0 A-6.0A / 8990W Art.No.873408 480V / 11A-5.5 A-5.5A / 8900W Art.No.873410400V / 16A-8.0 A-8.0A / 11072W Art.No.873411 480V / 13A-6.5 A-6.5A / 10700W Art.No.873415

Further Information

  • 325 EN – Siegling Blizzard Portable heating presses

    Siegling Blizzard - Portable Heating Presses
    Ref.- No. 325
    PDF | EN

  • Warning-Plagiarism_EN

    Warning About Counterfeit Products - Siegling Blizzard® Heating Presses
    PDF | EN

Siegling Blizzard HC 120/40

The new benchmark in efficient heating of splices Siegling Blizzard HC 120/40

The Siegling Blizzard HC is a new benchmark in quality and speed when heating splices for Siegling Extremultus belts in the aramide and polyester lines as well as narrow Siegling Transilon belts. It’s easy to handle and has very short cycles.


Get detailed information on how to use our Air-cooled Siegling Blizzard HC here – or download the App on your Mobile device using the QR-Code in the banner.

HC 120/40 QR image

Automatic heating and cooling in one single tool

  • prevents mistakes made during handling
  • saves having to put the belts and splicing guide into a cooling clamp after heating
  • is highly efficient due to short cycles
  • delivers excellent splicing results with superior repeat accuracy

Technical Information

Type designationBlizzard HC 120/40
Belt width max.[mm]40
Belt thickness[mm]1.3–3.2
Z-splices[mm]35:5.75
35:11.5
70:11.5
110:11.5
Heating temperature max.[°C]210
Total weight[kg]2.0
Dimensions (W x L x H)[mm]145 x 310 x 130



Power supply (alternative)
1 Phase (art.-no. 870187)[V/Hz]230/50
1 Phase (art.-no. 870188)[V/Hz]115/60

blizzard_hc_120_40_start_process.jpg
Blizzard HC 120/40 (Punch press: optional accessory)

Accessory for Siegling Blizzard HC 120/40

Splicing guides for Blizzard HC 120/40




Belt width [mm]
Belt thickness
1.3 to 3.2 mm

Article number
Belt thickness
2.5 to 5.0 mm

Article number
12870216870451
13870438-
15870170870452
16870439-
20870108870453
22870176870454
24870112870455
25870113870456
28870179870457
29870217870458
30870167870459
35870180870460
38870181870461
40870168870462
Plastic clamp870951870951

Siegling Blizzard HC live roller belt splicing set

suitable for splicing live roller belts up a belt width of 40 mm

Live roller belt splicing set 230 V
Art. no. 870494

Live roller belt splicing set 115 V
Art. no. 870495

The Blizzard HC live roller belt splicing set includes the following components:

QuantityUnitArticle
1ItemBlizzard HC 120/40 heating clamp
2ItemClips for the Blizzard heating clamp
1ItemPP-ZP-V/40-3 Z-punch press
1ItemPP-ZP-V/40-3 set of punching blades 110 x 11.5
1ItemBlizzard HC 120/40 splicing guide 30 mm
1ItemBlizzard HC 120/40 splicing guide 40 mm

Belt splicing set Blizzard HC 120/40

Further Information

  • 330 EN – The new benchmark in efficient heating of splices – Siegling Blizzard HC 120/40

    Siegling Blizzard HC 120/40
    Ref. no. 330 | PDF | EN

  • 288 EN / DE – User manual Blizzard Heating Clamp HC120/40

    User Manual – Blizzard Heating Clamp HC 120/40
    Ref. no. 288 | PDF | EN/DE

  • 289 EN – Siegling Blizzard Heating Clamp HC120/40 Quick reference guide

    Siegling Blizzard Heating Clamp HC 120/40 – Quick reference guide
    Ref. no. 289 | PDF | EN

  • A011 EN

    Data Sheet PP-ZP-V/40-3